MESH

FIBERGLASS MESH FOR WATERPROOFING APPLICATION


INTRODUCTION

Rockmax Mesh is a fiberglass mesh use in waterproofing application. The mesh increases reinforced, tensile, adhesion and puncture resistance to waterproofing system.

AREA OF USES

Rockmax Mesh can be used with
variety of waterproofing
materials such as Acrylic,
Ceramic, Polyurethane, Cement flexible, Liquid Modified Bitumen Waterproofing.

ADVANTAGES

  • Increase Puncture resistance.
  • Increase adhesion to substrate.
  • Good bonding between waterproofing material layers.
  • TECHNICAL PROPERTIES

    Color: White
    Width x Length: 1 meter x 100 meter
    Thickness: approx 0.22mm

    PACKAGING

    Roll: 1meter width x 100 meter length.

    STORAGE

    Storage in shade and dry condition at 10-30ºC. Avoid from sunlight, UV, frost, water, moisture and high temperature.

    EPOGARD W1

    Solvent Free Epoxy Coating For Drinking Water Retaining Structures


    INTRODUCTION

    Rockmax Epogard W1 is a two component, solvent free epoxy coating or lining. The cured material provides hard, gloss, smooth and watertight to concrete surfaces with and including abrasion and chemical resistance. It is suitable with potable or drinking water tank. The cured material is non-toxic.

    AREA OF USES

    Rockmax Epogard W1 is used for coating and lining concrete or steel surfaces such as waterproofing the internal of drinking water retaining tanks, waste water tanks, sewages, tunnels, reservoirs, retaining walls.

    ADVANTAGES

  • Excellent chemical resistance.
  • Excellent abrasion resistance.
  • Hard wearing surface.
  • Corrosion resistance.
  • Waterproof.
  • Food grade and hygienic.
  • Solvent free and non-toxic.
  • Protect moisture movement.
  • Easy for cleaning.
  • Good adhesion to concrete.
  •  

    APPLICATION AND INSTALLATION

    PREPARATION

    Concrete must be sound, clean and free from oil, grease, wax, cement paste, dust, dirt and any other contaminants. Concrete must be at least 28 days and minimum Compressive strength 25N/mm 2 and minimum tensile strength (pull off) at 1.5 N/mm 2 . The moisture content in concrete must be lower than 6%. The substrate should not have a relative humidity more than 85% at installation period. Total enclosed grinding, high water pressure jet, or scarifying must be employed followed by vacuuming. All holes and voids must be repaired prior to installation. Seal the surface with moisture barrier or modified epoxy cement in case of surface subject to rising damp or moisture movement. Please consult Rockmax for more information.

    PRIMING

    Apply Rockmax Epogard P by roller at one coat at approximate coverage rate 0.2 kg/m 2 . Allow the prime coat to dry approximate 4 hours. The difference type of primers must be considered according to substrate conditions.

    MIXING

    Stir base and hardener component separately approximate 10 second. Pour part A and part B together in the bucket and continue mixing for 3 minute until homogeneous. Avoid whipping air into the material. It is recommended that only full units to be used, that all components are thoroughly mixed. We do not recommend using partial kits and reduce or dilute materials.

    APPLICATION

    Applied Rockmax Epogard W1 by roller or stiff nylon type brush. Allow the first coat dry at approximate 5-6 hours (30ºC) and the second coat must be applied not more than 48 hours after the first coat application. When finished the application protect the coating from water.

    PACKAGING

    24kg set (A+B). Part A: 18kg and Part B: 6kg.

    STORAGE

    Storage in shade and dry condition. Avoid from frost, water, UV, moisture and high temperature.

    EPOGARD T

    Tar Epoxy Coating Chemical Resistance And Waterproofing Concrete


    INTRODUCTION

    Rockmax Epogard T is a two component epoxy coal tar waterproofing. Cured material provides high chemical resistance, good abrasion and durability to concrete structures. It can protect concrete from chemical s, dilute acids, salt waters, high chlorine concentrate, alkalis, solvents.

    AREA OF USES

    Rockmax Epogard T is used for coating and lining concrete such as water retaining tanks, waste water tanks, sewages, tunnels, reservoirs, retaining walls, septic tank, chemical tanks, sea water concrete structures, cooling tower tank.

    ADVANTAGES

  • Excellent chemical resistance.
  • Excellent abrasion resistance.
  • Protect against salt water attack.
  • Hard wearing surface.
  • Corrosion resistance.
  • Waterproof.
  • Protect moisture movement.
  • Good adhesion to concrete.
  • APPLICATION AND INSTALLATION

    PREPARATION

    Concrete must be sound, clean and free from oil, grease, wax, cement paste, dust, dirt and any other contaminants. Concrete must be at least 28 days and minimum Compressive strength 25N/mm 2 and minimum tensile strength (pull off) at 1.5 N/mm 2 . The moisture content in concrete must be lower than 6%. The substrate should not have a relative humidity more than 85% at installation period. Total enclosed grinding, high water pressure jet, or scarifying must be employed followed by vacuuming. All holes and voids must be repaired prior to installation. Seal the surface with moisture barrier or modified epoxy cement in case of surface subject to rising damp or moisture movement. Please consult Rockmax for more information.

    MIXING

    Stir base and hardener component separately approximate 10 second. Pour part A and part B together in the bucket and continue mixing for 3 minute until homogeneous. Avoid whipping air into the material. It is recommended that only full units to be used, that all components are thoroughly mixed. We do not recommend using partial kits and reduce or dilute materials.

    APPLICATION

    Applied Rockmax Epogard T by roller or stiff nylon type brush. Allow the first coat dry at approximate 12 hours (30ºC) and the second coat must be applied not more than 48 hours after the first coat application. When finished the application protect the coating from water.

    PACKAGING

    24.50 kg set (A+B).
    Part A: 21.0 kg and Part B: 3.50 kg.

    STORAGE

    Storage in shade and dry condition. Avoid from frost, water, UV, moisture and high temperature.

    MAXSHIELD 400S

    APP TORCH ON WATERPROOF ING SHEET MEMBRANE
    4mm THICKNESS WITH SAND OR SLATE FINISHED


    INTRODUCTION

    Maxshield 400S is an atatic polypropylene plastomeric (APP) modified bitumen waterproof sheet membrane and can be used for exposed surface. It is formulated from high grade modified bitumen with selected elastic polymer and reinforced with non woven polyester reinforcement. The membrane provides good elongation, high puncture resistance and good mechanical characteristic. The membrane top surface finished with special grade material such as sand or slate which can be exposed to the environmental with no require protections.

    AREA OF USES

  • Basements.
  • Tunnels.
  • Retaining walls.
  • Subways.
  • Below grade structures.
  • Balconies.
  • Roof.
  • Exposed roof desks.
  • Others.
  • ADVANTAGES

  • Good flexibility.
  • Good elongation.
  • Good elastic recovery.
  • High puncture resistance.
  • Good mechanical characteristic.
  • Will not decay.
  • Prefabricated membrane under     control quality.
  • Easy to torch on.
  • Widely use.
  •  

    APPLICATION AND INSTALLATION

    PREPARATION

    Concrete substrate must be at least 28 days old. Substrate must be sound, smooth, clean, dry and free from loose materials, oil, grease or any other contaminants. In case of substrate has moisture on surface use flame torch to dry up surface prior to apply primer.

    PRIMING

    Apply Maxshield Primer on prepared substrate at approximate coverage rate 5m2 per litre and allow to dry.

    APPLICATION

    Maxshield 400S should be install using gas torch. Slowly unrolled the membrane and flame torch the membrane until the bottom surface melt but do not over heat. Side overlap must be minimum 150mm. roll overlap joint must be minimum 100mm. Lap joint should be sealed by torch. All expansion joints, movement joints and all joints must be followed and allowed follow structural design. Other joints and end points must be allowed according to specifications. The membrane must be protected immediately after installation.

    Maxshield 400S must be installed by experiences, trained and approved applicators. Installation shall be strictly in accordance with manufacture method statement instruction.

    PACKAGING

    Roll size: 1meter x 10meter.
    Roll weight: approx 35kg.

    MAXSHIELD 300S

    APP TORCH ON WATERPROOF ING SHEET MEMBRANE


    INTRODUCTION

    Maxshield 300S is an atatic polypropylene plastomeric (APP) modified bitumen waterproof sheet membrane. It is formulated from high grade modified bitumen with selected elastic polymer and reinforced with non woven polyester reinforcement. The membrane provides good elongation, high puncture resistance and good mechanical characteristic. The membrane is top coated by sand or polyethylene (PE) and bottom surface protected by heat sensitive film.

    AREA OF USES

  • Basements.
  • Tunnels.
  • Retaining walls.
  • Subways.
  • Below grade structures.
  • Balconies.
  • Roof.
  • Others.
  • ADVANTAGES

  • Good flexibility.
  • Good elongation.
  • Good elastic recovery.
  • High puncture resistance.
  • Good mechanical characteristic.
  • Will not decay.
  • Prefabricated membrane under control quality.
  • Easy to torch on.
  •  

    APPLICATION AND INSTALLATION

    PREPARATION

    Concrete substrate must be at least 28 days old. Substrate must be sound, smooth, clean, dry and free from loose materials, oil, grease or any other contaminants. In case of substrate has moisture on surface use flame torch to dry up surface prior to apply primer.

    PRIMING

    Apply Maxshield Primer on prepared substrate at approximate coverage rate 5m2 per litre and allow to dry.

    APPLICATION

    Maxshield 300S should be install using gas torch. Slowly unrolled the membrane and flame torch the membrane until the bottom surface melt but do not over heat. Side overlap must be minimum 150mm. roll overlap joint must be minimum 100mm. Lap joint should be sealed by torch. All expansion joints, movement joints and all joints must be followed and allowed follow structural design. Other joints and end points must be allowed according to specifications. The membrane must be protected immediately after installation.

    Maxshield 300S must be installed by experiences, trained and approved applicators. Installation shall be strictly in accordance with manufacture method statement instruction.

    PACKAGING

    Roll size: 1meter x 10meter.
    Roll weight: approx 30kg.

    MAXSHIELD 150W

    SBS SELF ADHESIVE SHEET MEMBRANE


    INTRODUCTION

    Maxshield 150W is a cold applied self adhesive bituminous membranes. It is manufactured and formulated from modified SBS bitumen and high performance adhesive layer. This selected materials made very easy to installation. It is supplied in rolls 1meter width x 15meter long and 1.5mm thickness.

    AREA OF USES

  • Foundations.
  • Below grade structures.
  • Retaining walls.
  • Balcony.
  • Roof desks.
  • Flat roofs.
  • Planter boxes.
  • All concrete structures.
  • ADVANTAGES

  • Excellent adhesion to concrete.
  • Good flexibility.
  • Fast and easy installation.
  • Watertight.
  • Uniform thickness.
  • Resistance to acids and alkalis.
  • Nominal thickness 1.5mm.
  • APPLICATION AND INSTALLATION

    PREPARATION

    Concrete substrate must be sound, smooth, clean, dry and free from loose materials, oil, grease or any other contaminants. In case of substrate has moisture on surface use flame torch to dry up surface prior to apply primer.

    PRIMING

    Apply Maxshield Primer on prepared substrate at approximate coverage rate 5m2 per litre and allow to dry.

    APPLICATION

    Maxshield 150W should be applied from lowest point. All joints, angles and end points must be overlap at minimum 75mm. Internal and external corners should be reinforced with 300mm membrane strip. End laps should be sealed. Ensure the membrane is perfectly stick and adhere with concrete substrate and no air pockets. It is recommended to protect the membrane by protection boards immediately. Do not exposed the membrane to direct UV for long period. Maxshield 150W must be installed by experiences, trained and approved applicators.

    PACKAGING

    Roll size: 1meter x 15meter.
    Roll weight: approx 25kg.

    ROCKMAX WATERPLUG

    WATERPLUG


    INTRODUCTION

    Rockmax Waterplug is quick setting cement mortar for stop water leakage. Use to stop water passage through concrete structure, concrete joint and rock foundation.

    AREA OF USES

  • Culverts.
  • Basements.
  • Subways.
  • Underground works.
  • Leakage areas.
  • Swimming Pools.
  • ADVANTAGES

  • Very Fast setting.
  • Easy to use.
  • Good adhesion.
  • No corrosion.
  • No chloride.
  • Carry in small pack size
  • APPLICATION AND INSTALLATION

    PREPARATION

    Concrete substrate must be sound, clean, free from oil, grease, mould oil, dust, loose particles and cement paste. Ensure the surface is dry and free from water saturated.

    MIXING

    Mix Rockmax Waterplug with water at (water : waterplug = 1 : 5 by weight).

    APPLICATION

    Cut concrete substrate to receive V shape. Fill Rockmax Waterplug immediately after mixed. Wait for setting at 90 seconds. Remove all excess material on surface with and including leveling and making good surface.

    PACKAGING

    5Kg bag.

    ROCKMAX ROOFGARD

    ELASTOMERIC MODIFIED BITUMEN LIQUID MEMBRANE


    INTRODUCTION

    Rockmax Roofgard is one part thixotropic dark brown bitumen emulsion cold applied liquid membrane. Use for general purpose waterproofing material. Good bonding many kind of substrate ie concrete, asbestos concrete, roof felt, timber, galvanized roof, metal and etc.

    AREA OF USES

  • Roofs, gutters, walls.
  • Balconies.
  • Underground basements.
  • Damp-proofing.
  • External retaining wall.
  • ADVANTAGES

  • High elongation.
  • High elasticity.
  • Excellent crack bridging.
  • Excellent adhesion.
  • Easy to use.
  • Seamless waterproof.
  • Rust protection for galvanized and metal roofs.
  • Corrosion protection.
  • Can apply on old existing structure.
  • APPLICATION AND INSTALLATION

    PREPARATION

    Substrate must be sound, clean, free from oil, grease, mould oil, dust and loose particles. Ensure the surface is dry and free from water saturated.

    PRIMING

    Mixer must use low speed drill mixer (500 rpm) with and including good quality steel paddle. Make sure all tools and equipments are in good conditions and clean.

    Dilute Rockmax Roofgard with water at 1 (Rockmax Roofgard) : 1 (water) by volume. Stir 2 part together approximate 1-3 minute until homogenius. Prime the surface by brush or roller at coverage rate 0.5kg/m2. Allow the prime coat to dry before top coat application.

    APPLICATION

    Apply first coat of Rockmax Roofgard to the primed surface by brush or roller. Allow first coat to dry approximate 60-90 minute. Apply second coat and allow to dry. For watertight apply 2-3 coats. Allow to completely dry for 4-6 hours prior to light traffic

    CLEANING

    Clean all tools and equipments immediately with kerosene or solvent.

    PACKAGING

    18Kg pail.

    ROCKMAX CERAMIC V2

    ELASTOMERIC CERAMIC WATERPROOF COATING


    INTRODUCTION

    Rockmax Ceramic V2 is a high performance waterborne acrylic binder with and including air encapsulated ceramic microspheres which provide excellent heat reflection. The benefits also include excellent waterproofing, cost saving and reduce temperature inside the building. By using the coating, customers can efficiently stabilize proc esses, protect personnel and maintain product levels. Its designed for both spray and roller coating method.

    AREA OF USES

    Rockmax Ceramic V2 can used for the following flat exposed concrete roof, concrete gutter, steel gutter , façade , external concrete wall, roof metal sheet, steel tank , silos , electrical and mechanical room, area required control
    temperature.

    ADVANTAGES

  • Excellent heat reflective >80%.
  • Reduce temperature in building.
  • Excellent bonding.
  • Crack bridging ability.
  • Excellent elongation.
  • UV resistance.
  • Non yellowing.
  • Value engineering to building.
  • Reduce cost of air condition.
  • Reduce thermal shock.
  • Prevent rust and corrosion.
  • Long life span 10-15 years.
  • Easy application one part.
  • Can apply by spray.
  • Nice appearance.
  • APPLICATION AND INSTALLATION

    PREPARATION

    Concrete substrate must be sound, clean, free from oil, grease, mould oil, dust, loose particles, cement past and. Ensure the surface is dry and free from standing water. The moisture content in concrete substrate must be check with limit not more than 5% moisture contents. If moisture contents in concrete higher than 5% Moisture Barrier must be apply. Check and investigate void, honeycomb, or crack on concrete substrate. All damaged must be repair prior to application. All joints and corner must be treated with Rockmax PUseal. Others substrate such as metal, steel should be consult Rockmax for more information.

    PRIMING

    Rockmax Ceramic V2 can dilute with water and apply as first prime coat (20% thin with water). Apply prime coat by brush or spray to the whole area.

    APPLICATION

    Mixer must use low speed drill mixer (500 rpm) with and including good quality steel paddle. Make sure all tools and equipments are in good conditions and clean. Stir Rockmax Ceramic V2 by mixer at approximate 30 second until see homogeneous. Apply First coat of Rockmax Ceramic V2 by roller. Allow the first coat to dry at 2 hours before next coat. Apply second and third coat to achieve design thickness (DFT). Follow first coat application.

    Airless spray:
    In case of spray method. Thin 10% with clean water for easy working properties.

    CURING

    Protect Rockmax Ceramic V2 by plastic sheet from rain and water. Rockmax Ceramic V2 is self curing and curing time is approximate 5-7 days prior to open to traffic.

    PACKAGING

    23Kg pail.

    STORAGE

    Storage in shade and dry condition. Avoid from frost, water, UV, moisture and high temperature.

    ROCKMAX ROOFSEAL V1

    ELASTOMERIC ACRYLIC WATERPROOF



    INTRODUCTION

    Rockmax Roofseal V1 is one component water based acrylic liquid waterproofing membrane. The special integral micro reinforcement improves tensile strength and increase durability of coating. The product provides high elasticity and good watertight to its structure.

    AREA OF USES

  • Flat exposed concrete roof.
  • Concrete gutter.
  • Steel gutter.
  • Façade.
  • External wall cladding.
  • Metal Sheet roof.
  • External Wall.
  • ADVANTAGES

  • Excellent flexibility.
  • Excellent elongation.
  • Excellent adhesion.
  • Good tensile resistance.
  • Crack bridging ability.
  • UV resistance.
  • One part ready to use.
  • Durability.
  • Algae resistance.
  • Good puncture resistance.
  • Foot traffic.
  • Nice appearance.
  • APPLICATION AND INSTALLATION

    PREPARATION

    Concrete substrate must be sound, clean, free from oil, grease, mould oil, dust, loose particles and cement paste. Ensure the surface is dry and free from standing water. The moisture content in concrete substrate must be check with limited not more than 5% moisture contents. Investigate void, honeycomb, or crack on concrete substrate. All damaged must be repair prior to application. All joints and corner must be treated with Rockmax PUseal.

    PRIMING

    Apply one coat of dilute Rockmax Roofseal V1 with water at 1:1 ratio to prepared surface at approximate 0.2kg/m 2 per coat by roller. Allow the prime coat to dry at 1-3 hours prior to apply body coats.

    APPLICATION

    Mixer must use low speed drill mixer (500 rpm) with and including good quality steel paddle. Make sure all tools and equipments are in good conditions and clean. Stir Rockmax Roofseal V1 by mixer at approximate 1 minute until uniform homogeneous.

    Apply First coat of Rockmax Roofseal V1 by roller with coverage rate at 0.30 kg per m 2 per coat. Allow the first coat to dry at 2-4 hours before next coat. Apply second and third coat to achieve 1mm total thickness (DFT). Follow first coat application method. Fiber mesh might be used between the first coat and second coat. The thickness of product depends on number of coats, application method, substrate quality and other factors related to application. In case of spray method, please consult Rockmax for more information.

    PACKAGING

    23Kg pail.

    STORAGE

    Storage in shade and dry condition. Avoid from frost, water, UV, moisture and high temperature.